Line 18: Line 18:


TDO will have to be identified by impedence / voltage level testing.
TDO will have to be identified by impedence / voltage level testing.
The last two bits of the instruction register are always 01, so by shifting out the instruction register, activity should be seen on TDO.


TCK: Burst Clock for period of test
TCK: Burst Clock for period of test
Line 30: Line 28:
The '00000000' of TMS forces the TDI in, and the Current Instruction Out
The '00000000' of TMS forces the TDI in, and the Current Instruction Out


If the inputs pins are connected incorrectly at all, the worst that can happen is '0' can be clocked into TMS twice, which should force the machine to stay in it's Run-Test/Idle state.
If the inputs pins are connected incorrectly, the worst that can happen is '0' can be clocked into TMS twice, which should force the machine to stay in it's Run-Test/Idle state, and no damage can occur.


If the input pins are connected correctly, some data should be seen on TDO.
If the input pins are connected correctly, some data should be seen on TDO as the instruction register last two bits are always '01'.

Revision as of 00:48, 6 December 2006

Diagnostic

Presently, a possible location for the JTAG port has been identified, but which pin is which has not.

JTAG consists of 4 or 5 pins:

  • TRST - A Reset line, which could be tied low via an R, permanently disabling the JTAG interface.
  • TDI - Data In
  • TDO - Data Out
  • TMS - The Mode Select pin, which actually drives the JTAG TAP Controller around a simple state machine.
  • TCK - Clock

And Is Driven by a State Machine

JTAG-SM.png

Pin identification without risk of re-programming

TDO will have to be identified by impedence / voltage level testing.

TCK: Burst Clock for period of test TDI: 000000000000000000 .... TMS: 011111011000000000 ...

TDI & TMS Change on TCK falling. The '11111' of TMS forces the state machine to reset The '01100' of TMS forces it into the Shift-IR state The '00000000' of TMS forces the TDI in, and the Current Instruction Out

If the inputs pins are connected incorrectly, the worst that can happen is '0' can be clocked into TMS twice, which should force the machine to stay in it's Run-Test/Idle state, and no damage can occur.

If the input pins are connected correctly, some data should be seen on TDO as the instruction register last two bits are always '01'.